Put a loudspeaker in, and the receivers become required.
The federal standard is written against amplification rather than against seat count, and Florida adopted it as state law.
A general session is an assembly area, and §219.2 of the 2010 ADA Standards for Accessible Design requires an assistive listening system "in each assembly area where audible communication is integral to the use of the space." One exception is written into it, and it is the one that matters: other than in courtrooms, an assistive listening system "shall not be required where audio amplification is not provided."
So the obligation arrives with the public address system. A speech programme with a microphone and a pair of loudspeakers has crossed the line that an unamplified gathering of the same size has not. Every general session this company builds is on the required side of it, outdoors as much as indoors.
This is not a federal requirement that stops at the state line. Section 553.503, Florida Statutes, adopts the ADA Standards for Accessible Design and the related regulations in 28 C.F.R. parts 35 and 36 "by reference as the law of this state," and directs that they be incorporated into the Florida Accessibility Code for Building Construction. The table below is Florida law as well as federal.
Thirty-nine receivers for twelve hundred seats.
Table 219.3 is a stepped formula rather than a percentage, and the step changes four times as the plenary grows.
Table 219.3 of the Standards sets the minimum number of receivers against the capacity of the seating in the assembly area. Up to 50 seats it is two. From 51 to 500 it is two, plus one per 25 seats over 50 or fraction thereof. From 501 to 1,000 it is twenty, plus one per 33 seats over 500. From 1,001 to 2,000 it is thirty-five, plus one per 50 seats over 1,000. At 2,001 and over it is fifty-five, plus one per 100 seats over 2,000.
A 1,200-seat plenary therefore sits in the fourth band. Two hundred seats over the thousand, divided by fifty, is four. Thirty-five plus four is 39 receivers, and that is the number the equipment list has to carry to the site.
A second count rides on the first. §219.3 requires that twenty-five percent of the receivers provided, and no fewer than two, be hearing-aid compatible under §706.3, which means interfacing with the telecoil in a hearing aid through a neckloop. Thirty-nine divided by four is 9.75, and the table counts a fraction as a whole receiver, so ten of the thirty-nine arrive with neckloops. One exception removes that subset entirely: where every seat is served by an induction loop system, the hearing-aid-compatible minimum does not apply.
§706 then specifies the receivers themselves. Each includes a 1/8 inch, 3.2 mm, standard mono jack under §706.2. The system is capable of a sound pressure level of 110 dB minimum and 118 dB maximum with a 50 dB dynamic range on the volume control under §706.4. The signal-to-noise ratio for internally generated noise is 18 dB minimum under §706.5, and peak clipping stays within 18 dB of the peaks of speech under §706.6. Those four numbers are a specification, so they belong in the kit list rather than in the operator's judgement on the day.
One table follows the seats, the other follows the fixing.
A plenary on a flat floor carries the full receiver count, and the wheelchair-space table is written against a different condition.
Read the scope sentences of the two tables side by side and they do not cover the same ground. §219.2 applies in each assembly area where audible communication is integral, with no reference to how the seating is built. §221.2 opens differently: "Wheelchair spaces complying with 221.2 shall be provided in assembly areas with fixed seating."
For the work on this page that distinction does real scheduling work. A plenary built on an exhibit-hall floor, a civic hall, an arena floor or a tent deck arrives with loose chairs and no fixed seating, and the receiver count still follows every seat drawn on the plan. The chairs can move at rehearsal. The count on the equipment list cannot.
That is not a licence to leave accessibility out of a flat-floor drawing. §221.1 requires assembly areas to provide wheelchair spaces, companion seats and designated aisle seats complying with §221 and §802, and sends the reader to further requirements at 28 C.F.R. 35.151(g) and 28 C.F.R. 36.406(f). The practical reading is the one the fire side of this drawing already takes: read the sheet the authority having jurisdiction publishes before a seat count goes into a proposal. The widths, the ganging and the occupant-load factor that govern the same plan are set out in loose chairs or fixed seats.
Eleven wheelchair spaces, and eleven companion seats beside them.
In a house that is already seated the counts come off a second table and the positions are governed as well as the number.
Where the plenary lands in a theatre, an arena bowl or a civic hall with fixed seats, Table 221.2.1.1 sets the wheelchair spaces. Four to 25 seats is one. Twenty-six to 50 is two. Fifty-one to 150 is four, 151 to 300 is five, and 301 to 500 is six. From 501 to 5,000 it is six, plus one for each 150 seats or fraction thereof between 501 and 5,000.
The same 1,200 seats read against that band give seven hundred seats above five hundred. Seven hundred divided by 150 is 4.67, counted as five, and six plus five is 11 wheelchair spaces. §221.3 then adds at least one companion seat for each of them, so eleven spaces carry eleven companion seats.
Three more clauses decide where they sit, and they bear directly on a camera plot and a cable run. §221.2.2 requires the spaces to be an integral part of the seating plan, which the advisory to it reads as placed within the footprint of the seating area rather than outside it. §221.2.3.1 requires horizontal dispersion, with an exception in assembly areas of 300 or fewer seats where the spaces and companion seats sit within the second or third quartile of the total row length. And §221.4 designates at least five percent of the total aisle seats, chosen as the aisle seats closest to accessible routes and working outward from there.
An aisle is also the only place a cable crossover can sit, so the five percent and the dispersion are drawn at the same time as the front-of-house position rather than after it.
Infrared loses to sunlight, and the lawn needs a route.
Two clauses in the Standards speak directly to a plenary built on grass, and both change the order rather than the drawing.
A plenary inside a festival or a municipal programme often has no building at all. §221.5 covers that case by name: lawn seating areas and exterior overflow seating areas, where fixed seats are not provided, connect to an accessible route. The route is a construction item on the site plan, which on turf means the same matting and decking decision the stage build already carries.
The second clause is in the advisory to §706.1, and it settles a choice of technology outdoors. The advisory sets out the modes an assistive listening system can use — hard-wired, induction loop, infrared and FM radio — and states that an FM system "may be better than an infrared system in some open-air assemblies since infrared signals are less effective in sunlight." It adds the reverse case: infrared is typically the better choice where confidential transmission matters, because the signal stays inside the space it is thrown in.
So the same programme can want two different systems on the same day. An outdoor main-stage plenary at two in the afternoon points at FM. A closed session in a divided hall points at infrared, which does not pass through the partition. Both decisions are made at the site survey, because they change what arrives on the truck.
Ninety-six receivers, or fifty-nine on one condition.
One exception to Table 219.3 pools the count across a whole building, and it is bought with a single specification decision.
A conference programme is rarely one space. Where a building holds more than one assembly area and the areas required to provide assistive listening are under one management, §219.3 permits the total number of receivers to be calculated on the total number of seats in those areas — "provided that all receivers are usable with all systems."
That proviso carries the exception, and the arithmetic shows what it is worth. Take the 1,200-seat plenary with nineteen 60-seat breakouts beside it. Counted area by area, the plenary takes 39 and each 60-seat breakout sits in the 51-to-200 band at two plus one per 25 seats over fifty, which is three. Nineteen threes is fifty-seven. Thirty-nine and fifty-seven is 96 receivers.
Counted as one pool, the same programme is 1,200 seats plus 1,140, or 2,340, which falls in the 2,001-and-over band at fifty-five plus one per 100 seats over 2,000. Three hundred and forty divided by a hundred is 3.4, counted as four, and fifty-five plus four is 59 receivers. The hearing-aid-compatible subset moves with it, from forty-eight counted separately to fifteen pooled.
Thirty-seven receivers and a charging plan turn on one sentence, and the sentence is a specification rather than a paperwork exercise. Pooling is available where every receiver works with every system, so a plenary on FM and a breakout floor on infrared cannot pool, and the choice is made before anything is ordered. What the building publishes about the spaces themselves — the rigging exclusives, the partition, the dock count — is read in one hall or nineteen.
The building's alarm is read against your programme level.
Two clauses in the Florida Building Code are written against the ambient level in the space, and a general session is what sets it.
A general session is a Group A assembly occupancy, and §907.2.1 of the 2023 Florida Building Code, Building, requires a manual fire alarm system that activates the occupant notification system "where the occupant load due to the assembly occupancy is 300 or more." §907.2.1.1 sets a second threshold above it. At an occupant load of 1,000 or more, activation "shall initiate a signal using an emergency voice/alarm communications system." The seat count on the general session drawing is what crosses that line, and the occupant-load factor that turns square footage into that number is already published by the authority.
§907.5.2.1.1 sets the level those appliances have to reach, and it is written against the space rather than against the equipment. The audible appliances "shall provide a sound pressure level of 15 decibels (dBA) above the average ambient sound level or 5 dBA above the maximum sound level having a duration of not less than 60 seconds, whichever is greater, in every occupiable space within the building." While a general session is running, the programme audio is the ambient sound level. A level held for a minute during a walk-in or a keynote sets the second test, and 5 dBA above a sustained 95 dBA is 100 dBA, required at every seat rather than at the mix position.
The next clause sets a ceiling on it. §907.5.2.1.2 holds the total of the ambient level combined with all audible notification appliances operating to 110 dBA at the minimum hearing distance from the appliance. It then names the level at which the audible alarm stops being the answer: where the average ambient noise is greater than 105 dBA, "visible alarm notification appliances shall be provided in accordance with NFPA 72 and audible alarm notification appliances shall not be required." The 110 dB minimum quoted in the receiver specification further up this page is a different figure, and it governs a different piece of equipment.
Where the house voice system also carries the show's announcements, precedence is published rather than agreed on the day. §907.5.2.2.3 allows the emergency voice/alarm communication system to be used for other announcements, "provided the manual fire alarm use takes precedence over any other use." The live-voice exception in §907.2.1.1 is narrow. A prerecorded announcement may be manually deactivated for a period "not to exceed 3 minutes, for the sole purpose of allowing a live voice announcement from an approved, constantly attended location." A show-caller's position is that location only where the authority having jurisdiction has approved it as one.
Three questions therefore belong on the site survey rather than on the run sheet. What the installed notification system in the space is, which the facility's own fire plan states. What the occupant load on the seating drawing comes to, because 300 and 1,000 are both published thresholds. And what sustained level the programme is mixed at, because both of the clauses above read it.
Twelve feet of image, before the back row reads a slide.
AVIXA publishes a table for this and it stops at a viewing ratio of ten. A large general session reaches that before the seating does.
The lede on this page says the seat count sets the screen as well as the audio, and the figure that does it is published. AVIXA's own standards pages carry the display-image-size standard and its calculators, printing the designation as ANSI/AVIXA V202.01:2026 in the listing and as ANSI/INFOCOMM V202.01:2026 under the analytical heading. The quantity it turns on is the viewing ratio, and AVIXA states the arithmetic in one line: "The Viewing Ratio is calculated as the Farthest Viewer/Image Height." The back seat and the image height are the only two numbers in it, and both are drawn before a chair is placed.
Two acuity factors sit under that ratio, and one is seventeen times the other. AVIXA publishes both: "The Acuity Factor for Basic Decision Making is 200. The Acuity Factor for Analytical Decision Making is 3438." A keynote headline, an agenda slide and a presenter's name are basic decision making. A spreadsheet, a schedule or a drawing read off the screen is analytical. The same general session can want two different screen heights in one day, and which one it wants is a question about the content rather than about the space.
For basic decision making the standard publishes a table rather than a single ratio. Against an acuity of 200 it pairs each band of viewing ratio with a minimum %Element Height, where AVIXA defines an element as "a group of pixels conveying an item of information" and the %Element Height factor as "the ratio of element height to screen height expressed as a percentage." The ladder reads 0.50% below a ratio of 1.00, 0.75% to 1.50 and 1.00% to 2.00, and from there half a point of element height for each whole step of ratio, reaching 5.00% at a ratio of 9.00 to 10.00. AVIXA adds that users "should vary this percentage according to the content", so the table is a floor and not a specification.
Put the 1,200-seat general session from §02 against that table. Take the back seat at 120 feet, which a plenary on an exhibit-hall floor or an arena floor reaches easily. A 12-foot image height gives a viewing ratio of 10.00, the last row the table has. A 9-foot image gives 13.3, which is off the end of it. The published table runs out before the seating block does, and 12 feet is the smallest image the basic-decision-making ladder will still score at that distance.
The last row then sets the type. At a ratio of 9.00 to 10.00 the minimum element height is 5.00% of screen height. Five percent of a 12-foot image is 7.2 inches, and in a 1,080-line frame it is 54 lines of pixels. A deck authored at 1920 by 1080 with 24-pixel body type does not reach it, which makes the presenter template a production decision taken weeks before anybody hangs a screen. The ratios this site already publishes for IMAG are the companion figure to this one.
Width is governed as well, and by the image rather than by the building. AVIXA defines the horizontal viewing area as "the area bounded by a line drawn 60 degrees from the perpendicular of each edge of the image to determine Closest Viewer." On a flat floor with loose chairs that line is the one to draw first. A seat outside the wedge the screen's own edges open is outside the area the standard uses, however well the chair plan fits the space, so a general session seated to the width of the hall and not to the width of the picture puts its last chairs where the standard stops.
Three numbers therefore come off the same drawing before the chairs do. The farthest seat, which sets the ratio. The image height that ratio allows, which sets the screen and with it the trim height and the load above it. And the smallest element on the busiest slide, which the template has to carry. What holds that screen once it has a height is a separate published limit.
Eight answers, and every one of them is published.
Every one of them is answered by a table or a clause, and every one changes a count on the equipment list.
Whether there is amplification
§219.2 requires nothing where no audio amplification is provided
How many seats you drew
Table 219.3 steps four times between 50 seats and 2,000
Whether the seats are fixed
§221.2 is written against assembly areas with fixed seating
Indoors or in sunlight
The §706.1 advisory puts FM ahead of infrared in open air
One space or several
Pooling needs every receiver usable with every system
Who the AHJ is
§221.1 sends the flat-floor case to 28 C.F.R. 35.151(g)
What the programme is mixed at
§907.5.2.1.1 reads the ambient level in the space, not the equipment
How far the back seat is
AVIXA's viewing-ratio table stops at 10.00, which 12 feet of image reaches at 120 feet
Where the figures come from
- The trigger, and Florida adopting it — 2010 ADA Standards for Accessible Design, §219.1 and §219.2 (an assistive listening system in each assembly area where audible communication is integral to the use of the space, with the exception that other than in courtrooms a system is not required where audio amplification is not provided), ada.gov, read 8 November 2026. Section 553.503, Florida Statutes, Adoption of federal standards — the ADA Standards for Accessible Design and the related regulations in 28 C.F.R. parts 35 and 36 and 49 C.F.R. part 37 adopted and incorporated by reference as the law of this state, flsenate.gov.
- 39 receivers, 10 with neckloops — Table 219.3, Receivers for Assistive Listening Systems — 50 or less, 2; 51 to 500, 2 plus 1 per 25 seats over 50 or fraction thereof; 501 to 1,000, 20 plus 1 per 33 seats over 500; 1,001 to 2,000, 35 plus 1 per 50 seats over 1,000; 2,001 and over, 55 plus 1 per 100 seats over 2,000. §219.3 — 25 percent minimum of receivers provided, and no fewer than two, hearing-aid compatible in accordance with §706.3, at 1 per 4 receivers or fraction thereof, with the exception that the subset is not required where all seats are served by an induction loop system. §706.3 — hearing-aid-compatible receivers interface with telecoils through neckloops. The 39 and the 10 are that table applied to 1,200 seats on this page.
- The receiver specification — §706.2 (a 1/8 inch, 3.2 mm, standard mono jack), §706.4 (sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB), §706.5 (signal-to-noise ratio for internally generated noise, 18 dB minimum) and §706.6 (peak clipping not exceeding 18 dB relative to the peaks of speech).
- Fixed seating, and the flat-floor pointer — §221.1 (assembly areas provide wheelchair spaces, companion seats and designated aisle seats complying with §221 and §802, with additional requirements at 28 C.F.R. 35.151(g) and 28 C.F.R. 36.406(f)) and the scope sentence of §221.2 (wheelchair spaces provided in assembly areas with fixed seating).
- 11 wheelchair spaces, 11 companion seats, 5 percent of aisle seats — Table 221.2.1.1, Number of Wheelchair Spaces in Assembly Areas — 4 to 25, 1; 26 to 50, 2; 51 to 150, 4; 151 to 300, 5; 301 to 500, 6; 501 to 5,000, 6 plus 1 for each 150 or fraction thereof between 501 and 5,000; 5,001 and over, 36 plus 1 for each 200 or fraction thereof over 5,000. §221.3 (at least one companion seat for each required wheelchair space), §221.2.2 and its advisory (an integral part of the seating plan, within the footprint of the seating area), §221.2.3.1 and its exception (horizontal dispersion, with the second-and-third-quartile exception at 300 or fewer seats) and §221.4 (at least 5 percent of the total aisle seats, being those closest to accessible routes). The 11 is that table applied to 1,200 seats on this page.
- Lawn seating, and FM against infrared — §221.5 (lawn seating areas and exterior overflow seating areas, where fixed seats are not provided, connect to an accessible route) and Advisory 706.1 (hard-wired, induction loop, infrared and FM transmission; an FM system may be better than an infrared system in some open-air assemblies since infrared signals are less effective in sunlight, and an infrared system is typically the better choice where confidential transmission is important because it is contained within a given space).
- 96 against 59, and the proviso — The first exception to §219.3 — where a building contains more than one assembly area and the assembly areas required to provide assistive listening systems are under one management, the total number of required receivers may be calculated according to the total number of seats in the assembly areas in the building, provided that all receivers are usable with all systems. The 96, the 59, the 48 and the 15 are Table 219.3 applied on this page to a 1,200-seat plenary with nineteen 60-seat breakouts, counted area by area and then pooled.
- The 300 and the 1,000 — 2023 Florida Building Code, Building, 8th Edition, §907.2.1 Group A (a manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 shall be installed in Group A occupancies where the occupant load due to the assembly occupancy is 300 or more, or where the Group A occupant load is more than 100 persons above or below the lowest level of exit discharge) and §907.2.1.1 System Initiation in Group A Occupancies With an Occupant Load of 1,000 or More (activation shall initiate a signal using an emergency voice/alarm communications system in accordance with Section 907.5.2.2), read 14 November 2026. The Florida Building Code is adopted by the Florida Building Commission under section 553.73, Florida Statutes, which directs the commission to adopt an updated code through review of the most current updates of the International Building Code, flsenate.gov.
- 100 dBA at every seat, and the 105 dBA switch — §907.5.2.1.1 Average Sound Pressure — the audible alarm notification appliances shall provide a sound pressure level of 15 decibels (dBA) above the average ambient sound level or 5 dBA above the maximum sound level having a duration of not less than 60 seconds, whichever is greater, in every occupiable space within the building. §907.5.2.1.2 Maximum Sound Pressure — the total sound pressure level produced by combining the ambient sound pressure level with all audible notification appliances operating shall not exceed 110 dBA at the minimum hearing distance from the audible appliance, and where the average ambient noise is greater than 105 dBA, visible alarm notification appliances shall be provided in accordance with NFPA 72 and audible alarm notification appliances shall not be required. The 100 dBA is 5 dBA above a sustained 95 dBA programme level, applied on this page.
- The viewing ratio, and the standard’s own designation — AVIXA, Display Image Size for 2D Content in Audiovisual Systems — “The Viewing Ratio is calculated as the Farthest Viewer/Image Height.” AVIXA’s DISCAS standards and calculator pages print the designation two ways, as ANSI/AVIXA V202.01:2026 in the standard’s own listing and as ANSI/INFOCOMM V202.01:2026 under the analytical decision-making heading; both spellings are reproduced here rather than one being chosen. avixa.org, read 17 November 2026.
- 200 against 3438 — AVIXA, Display Image Size — “The Acuity Factor for Basic Decision Making is 200. The Acuity Factor for Analytical Decision Making is 3438.” The same page defines an element as “a group of pixels conveying an item of information” and the BDM %Element Height factor as “the ratio of element height to screen height expressed as a percentage”, and states that users “should vary this percentage according to the content”. avixa.org, read 17 November 2026.
- 0.50% to 5.00% of screen height — AVIXA’s published table for BDM at an acuity of 200 pairs each band of viewing ratio with a minimum %Element Height: 0.50% at a ratio of 0.80 to 1.00, 0.75% to 1.50, 1.00% to 2.00, then 1.50% to 3.00 and half a point more of element height for each whole step of ratio above that, to 5.00% at a ratio of 9.00 to 10.00, where the table ends. avixa.org, read 17 November 2026.
- The 60-degree wedge — AVIXA, Display Image Size — Horizontal Viewing Area, “the area bounded by a line drawn 60 degrees from the perpendicular of each edge of the image to determine Closest Viewer.” avixa.org, read 17 November 2026.
- 12 feet, 7.2 inches and 54 lines — That table applied on this page to a back seat at 120 feet. 120 divided by 12 is a viewing ratio of 10.00, the last row; 120 divided by 9 is 13.3, past the end of it. 5.00% of a 12-foot image is 7.2 inches, and 5.00% of 1,080 lines is 54. The 120 feet is this page’s own example rather than a figure from the standard.
- Precedence, and the three minutes — §907.5.2.2.3 Alternate Uses — the emergency voice/alarm communication system shall be allowed to be used for other announcements, provided the manual fire alarm use takes precedence over any other use. The exception to §907.2.1.1 — where approved, the prerecorded announcement is allowed to be manually deactivated for a period of time, not to exceed 3 minutes, for the sole purpose of allowing a live voice announcement from an approved, constantly attended location.