One arena publishes 4,500 pounds per point and 120,000 pounds across the grid.
The other says the roof supports a theatrical grid and asks you to call about the weight.
Addition Financial Arena, on the University of Central Florida campus, publishes its rigging capacity in its own promoter guide. Each panel point can hold 4,500 pounds per panel point, and the total rigging grid can hold up to 120,000 pounds. Most bays measure 16 feet by 12 feet, which the guide says gives the ability to make most of the points dead hangs, and most points will be hung from the low steel.
That is enough to draw a plot against. A ceremony carries less weight than a touring rock show, but it carries it in awkward places: a line array either side of a proscenium that does not exist, a centre screen, a pair of side screens, and a lighting position that has to stay off the faces of people walking a procession. Knowing the per-point figure before the drawing is started settles how many points the design is allowed to ask for.
The Stephen C. O’Connell Center at the University of Florida publishes the opposite. Its own rental page states that the roof supports a theatrical grid system and then asks the reader to contact the building for more details regarding the weight capacity. Every height is published and the capacity is not. A plot drawn for that room is provisional until somebody at the building answers an email, and the date of the ceremony does not move while that happens.
The asymmetry is the planning fact. Two public universities in the same state, both with a published facility page, and only one of them lets a production company cost a rigging plan from a desk.
There are no East to West beams to rig off of in the UCF arena.
An arch roof also means the steel is at two heights, and the plot has to pick one.
The same paragraph that gives the capacity gives a shape. The guide states there are no East to West beams to rig off of, so every point hangs from steel running the other way. A design that wants a straight upstage truss across the short axis of the room is asking for something the building does not have, and that is discoverable before the drawing rather than at the production meeting.
The height comes in two figures because the roof curves. Distance from the arena floor to low steel is 54 to 58 feet due to an arch roof, and distance from floor to high steel is 67 to 71 feet. The guide adds that most points will be hung from the low steel, which is the figure a trim height should be measured against. The scoreboard trim clearance height is 38 feet, and the scoreboard is usually the thing a centre screen has to live under or instead of.
For contrast, the O’Connell Center publishes floor to grid at 76 feet 6 inches and floor to roof at 118 feet. A taller room with an unpublished capacity is not a more useful room to plan in.
The bay door to the arena floor is 12 feet high. The bleacher height inside it is 9 feet 6 inches.
The published door dimension and the published usable dimension are two different numbers, in the same table.
The UCF guide lists four bay doors on a dock on the north-west side of the building. Bay doors 1 and 2 are 8 feet wide by 10 feet high, bay door 3 is 9.5 feet by 12 feet, and bay door 4 is 12 feet by 12 feet. Three of the four have dock levelling and one sits at ground height.
Then the line that catches a truck pack. Bay door to arena floor is 15.5 feet wide by 12 feet high, and the bleacher height inside the door is 9 feet 6 inches. The route in is briefly two feet six inches lower than the door that leads to it. Anything built tall on a dolly — a line array in a cart, a stacked riser, a dressed lectern — is measured against the 9 feet 6 inches rather than against the door.
The distances are published too, and they are the ones that decide how long a load-in takes rather than whether it fits. Push from the loading dock to the arena floor is 43 feet. Distance from the loading dock bay door to the front of house mix is 90 feet. The guide says there is adequate parking to unload up to four trucks at one time.
Where the freight elevator has to carry anything, it is rated at 4,500 pounds, measures 5 feet 8 inches wide by 8 feet 8 inches deep by 7 feet 4 inches high, and its access door is 4 feet wide by 7 feet high. A 4-foot door sets the real limit on what goes upstairs, whatever the car behind it will hold.
At the O’Connell Center the floor sits 14 and a half feet below ground level.
Trucks reach the floor and the audience arrives a storey above it.
The O’Connell Center publishes an unusual vertical arrangement and the reason for it. Three levels of seating surround the main arena floor, which is 14.5 feet below ground level to take advantage of the constant temperature of the earth.
The level map is what matters on the day. Level 1 is the main arena floor and the loading dock is located on this level. Level 2 is street level, where patrons enter the building when arriving for an event, and it carries the main concourse and the parking. Level 3 can only be accessed via staircases or elevators within the arena.
So the production route and the audience route are on different floors for the whole build, which is easier than it sounds rather than harder: a dock that opens onto the performance floor removes the ramp, the lift and the shared doorway that a street-level arena makes a crew negotiate. The published floor itself is 172 feet by 118 feet with the bleachers in and 130 feet by 74 feet with them out, and the second figure is the one a graduation seating plan actually gets.
Three 400-amp services, one 300, four 200 — all of it 75 feet from stage centre.
The distance is published alongside the rating, and the distance is the part that costs cable.
UCF publishes show power in all four corners of the floor: three 400-amp services, one 300-amp, and four 200-amp services, all three phase at 120/208 volts. Power is located 75 feet from stage centre. Two additional 400-amp services are located 75 feet from the front of house mix. Power connections are all camlock.
A ceremony rarely troubles those ratings. It does trouble the geometry, because 75 feet from stage centre in four corners means the feeder run is known before anybody asks, and a mix position with its own pair of 400-amp services is a different cable plan from one fed off the stage.
Shore power is published separately for buses and television production trucks, at one 400-amp and one 200-amp, all three phase. For a commencement that is where a broadcast or streaming truck lands, and it is a published figure rather than a question for the week of.
Basketball seats 10,136 in the same room a speech seats 6,000 to 7,000.
The athletic capacity and the ceremony capacity are both published, and they are four thousand seats apart.
The O’Connell Center publishes its capacities by event type, and the spread is the useful part. Men’s basketball, women’s basketball and volleyball are each 10,136. Gymnastics is 9,251. Swim and dive is 1,005. With all of the seating in use the main arena can accommodate almost 10,500 spectators.
Speaking engagements are published lower, and in two configurations: a side-stage set at 2,500 to 3,500 and a full house at 6,000 to 7,000. Concerts land between, at 6,200 to 6,400 for a full house with 180 degree scaling and 10,500 in the round. Banquets are up to 1,200.
A commencement is a speaking engagement with a stage, so the figure a university should be planning tickets against is the 6,000 to 7,000 rather than the 10,136 on the athletics page. The difference is sightlines, and sightlines are set by where the platform goes, which is a production decision taken months before anybody counts guests per graduate.
UCF publishes the floor rather than the ceremony. Its arena main floor is 16,235 square feet at 191 feet by 85 feet with the north and south seats retracted, and 10,540 square feet at 124 feet by 85 feet with all seats pushed out. The floor load is 250 pounds per square foot, and fixed seating is 9,465 seats.
Special permits go to the university’s own environmental health office, 30 days prior.
A campus arena answers to a department that a city venue does not have.
The UCF guide routes special permit applications to the Department of Environmental Health and Safety on the campus of the University of Central Florida, and states that all permits need to be submitted thirty days prior to the event. That is a campus office rather than a city building department, and it is a deadline that runs on the ceremony date rather than on a permit queue.
The published trigger list reaches further into a production than a fire-code reading suggests. It covers display or operation of any unusual electrical, mechanical or chemical device which may present a hazard; any heater, barbeque, open flame, candles, lamps or torches; use or storage of flammable liquids, compressed gases or dangerous chemicals; any pyrotechnics, fireworks or special effects display or process; any unusual use of motorized vehicle inside a structure; and tents in excess of 100 square feet erected inside or outside the facility.
The motorized-vehicle line is the one a production team reads twice. A scissor lift or a forklift working inside the bowl to build the stage is a motorized vehicle inside a structure, and a build that needs one is reading a 30-day clock that starts long before the trucks are booked.
Labour is published as closed. The guide names the arena’s operator as in contract with IATSE, describes it as a union labour workforce, and states that all labour needs will go through your event manager and the facility at all times. The rigging plan is closed the same way: all show rigging plans, including the weight of each point, must be submitted to and approved by arena management before any rigging is done.
A ceremony cannot move, so everything that can be settled early should be. Two Florida public university arenas publish the same kind of page and answer different questions on it: one gives a per-point weight, a grid total, a beam direction, two steel heights, a dock distance and a permit deadline, and the other gives heights, a floor size and a list of capacities with the rigging capacity held back. Read the building’s own page before the drawing starts. Where the weight is published, the plot can be costed from a desk; where it is not, the first email is the long pole.
Where the figures come from
- 4,500 pounds per panel point; total rigging grid up to 120,000 pounds; most bays 16 feet by 12 feet; no East to West beams; floor to low steel 54 to 58 feet and floor to high steel 67 to 71 feet due to an arch roof; scoreboard trim clearance 38 feet; bay door to arena floor 15.5 feet wide by 12 feet high with bleacher height inside the door 9 feet 6 inches; push from loading dock to arena floor 43 feet; loading dock bay door to front of house mix 90 feet; freight elevator 4,500 pounds at 5 feet 8 inches by 8 feet 8 inches by 7 feet 4 inches with a 4-foot access door; three 400-amp, one 300-amp and four 200-amp services, three phase 120/208 volts, 75 feet from stage centre, camlock connections; arena main floor 16,235 square feet and 10,540 square feet; floor load 250 pounds per square foot; fixed seating 9,465; IATSE contract; special permits to campus Environmental Health and Safety thirty days prior. — Addition Financial Arena, Promoter Guide REV 11.26, additionfiarena.com, read on 20 November 2026.
- The roof supports a theatrical grid system, with weight capacity available on request rather than published; floor to grid 76 feet 6 inches; floor to roof 118 feet; floor to Level 2 15 feet; main arena floor 14.5 feet below ground level; loading dock on Level 1 with patrons entering on Level 2 at street level; floor 172 feet by 118 feet with bleachers in and 130 feet by 74 feet with them out; basketball and volleyball 10,136; gymnastics 9,251; swim and dive 1,005; almost 10,500 with all seating in use; speaking engagements 2,500 to 3,500 side-stage and 6,000 to 7,000 full house; concerts 6,200 to 6,400 at 180 degree scaling and 10,500 in the round; banquets up to 1,200. — Stephen C. O’Connell Center, University of Florida, Rent the Center, oconnellcenter.ufl.edu, read on 20 November 2026.